Pre-startup Preparations
Personnel Preparation: Operators must be professionally trained and certified; they must wear compliant personal protective equipment (PPE) such as hard hats, dust masks, and protective gloves. Long hair must be tucked inside the hat, and any jewelry or accessories prone to getting caught in machinery must be removed.
Equipment Inspection: Check that all mechanical components are securely fastened, electrical wiring shows no signs of exposure or wear, the emergency stop button functions correctly, and pneumatic/hydraulic system pressures are within rated ranges.
Parameter and Material Verification: Configure parameters such as target packaging weight and feed rate via the PLC system; verify that packaging material specifications match the product to be packaged; and clear the work area of debris to ensure unobstructed access.
No-load Test Run: Start the equipment and run it without load for 1–2 minutes to confirm smooth operation without abnormal noise; conduct a trial run with a small batch of samples to verify that packaging quality meets standards.
Standard Operating Procedures During Operation
Sequential Startup: Start the systems in the following order: dust collection system → material feeding system → conveying system → main packaging unit. Proceed to the actual packaging process only after all systems are running stably.
Process Monitoring: Monitor the equipment's operating status continuously; do not leave the workstation without authorization. Strictly prohibit inserting hands or foreign objects into hazardous areas such as bag-clamping mechanisms or screw-feeding devices.
Parameter Adjustment: If packaging parameters need adjustment, stop the machine or reduce its speed first. After adjustment, perform a test run to verify accuracy before resuming normal operation.
Handling Abnormalities: In the event of malfunctions such as material jams, abnormal noises, or leaks, immediately press the emergency stop button and disconnect the power and air supplies before troubleshooting or repairs. Operating the equipment while a fault exists is strictly prohibited.